Probe Termistor NTC 10KΩ 3950K 6.5x25mm Dilipat PVC
Detail produk:
Nama merek: | Aolittel |
Nomor model: | CWFM0103FC1-202M113X |
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: | 1000 buah |
---|---|
Harga: | Negotiable |
Kemasan rincian: | Jumlah besar |
Waktu pengiriman: | 2-4 minggu |
Syarat-syarat pembayaran: | T / T |
Menyediakan kemampuan: | 1.000.000 Potongan Per Bulan |
Informasi Detail |
|||
Nama Artikel: | Pemeriksaan Sensor Suhu Mikro Jarak Jauh Lantai | R25: | 10KΩ ± 1% |
---|---|---|---|
B25 / 50: | 3950K ± 1% | Probe diameter: | 6.5mm |
Panjang pemeriksaan: | 20mm | Kisaran Temp: | -30 ~ + 105C |
Menahan tegangan: | 1500VAC 2Sec | Kecepatan respons: | 15 detik |
Cahaya Tinggi: | Probe termistor 25mm ntc,probe termistor 3950K ntc,sensor suhu 25mm ntc |
Deskripsi Produk
Probe Termistor NTC 10KΩ 3950K 6.5x25mm Dilipat PVC
PVC Overmolded Remote Room Thermostat Penghangat Ruangan Kabel Pemanas Undefloor Sensor Suhu Mikro Probe 10KΩ 3950K 6.5x25mm
Gambaran
Probe dan Sensor digunakan untuk mengontrol suhu di mana kelembaban akan menjadi masalah, misalnya di kamar basah atau kamar mandi.Itu juga dapat mengontrol suhu lantai di mana panas berlebih akan menyebabkan kerusakan.
______________________________________________________________________________ Unduh________
Bahan
TIDAK | nama material | Bahan dan Spesifikasi |
1. | Elemen | R25 = 10KΩ ± 1% B25 / 50 = 3950K ± 1% DC |
2. | Lapisan | NTC dienkapsulasi menggunakan bahan over-mould PVC (Putih) |
3 | Fitur kabel |
UL2464-22AWG Kabel tembaga lapis timah dengan kawat jaket datar PVC putih 80 ℃ 300V
|
4. | Kabel berakhir | Yg dikalengi |
Dimensi | ||||
SEBUAH | B | C | D | L |
6.5 | 20 | 25 ± 5 | 3 ± 1 | seperti yang dipersyaratkan |
Pertunjukan
TIDAK | Barang | Tanda | Kondisi Tes | Min. | Maupun. | Max. | Satuan |
1. | Resistensi di 25 ℃ | R25 |
Ta = 25 ± 0,05 ℃ P.T≦ 0.1mw |
9.9 | 10.0 | 10.1 | kΩ |
2. | Nilai B | B25 / 50 | 3910.5 | 3950 | 3989,5 | k | |
3. | Faktor disipasi | σ | Di udara diam | Tentang 2 | mW / ℃ | ||
4. | Respon waktu | τ | Di air mengalir | Sekitar 15 | detik | ||
5. | Tegangan Tahan | / | 1500VAC 2Sec | Tidak ada kerusakan | Detik | ||
6. | Resistensi Isolasi | 500VDC | ≧ 100 | MΩ | |||
7. | Suhu operasi.jarak | / | / | -30 | / | +105 | ℃ |
Pemasangan Dinding Kering & Padat
Minco Heat 0.5M2 Twin-Conductor Electric Underfloor Heating Mats Untuk Lantai Hangat, Kit Pemanas Di Bawah Lantai
Resistensi Vs.Tabel Suhu
R - T TABEL KONVERSI | ||||||||
R25= 10KΩ ± 1% B25/50= 3950K ± 1% | ||||||||
T / ℃ | Rmin | Rcen | Rmax | T / ℃ | Rmin | Rcen | Rmax | |
-40 | 335.811 | 351.495 | 367.875 | -5 | 41.735 | 42.774 | 43.834 | |
-39 | 314.029 | 328.472 | 343.546 | -4 | 39.599 | 40.563 | 41.547 | |
-38 | 293.803 | 307.110 | 320.988 | -3 | 37.586 | 38.480 | 39.392 | |
-37 | 275.015 | 287.279 | 300.060 | -2 | 35.686 | 36.517 | 37.363 | |
-36 | 257.552 | 268.859 | 280.635 | -1 | 33.894 | 34.665 | 35.450 | |
-35 | 241.313 | 251.741 | 262.595 | 0 | 32.203 | 32.919 | 33.646 | |
-34 | 226.204 | 235.826 | 245.832 | 1 | 30.607 | 31.270 | 31.945 | |
-33 | 212.141 | 221.021 | 230.250 | 2 | 29.099 | 29.715 | 30.340 | |
-32 | 199.044 | 207.242 | 215.757 | 3 | 27.674 | 28.246 | 28.826 | |
-31 | 186.841 | 194.412 | 202.270 | 4 | 26.328 | 26.858 | 27.396 | |
-30 | 175.465 | 182.460 | 189.714 | 5 | 25.055 | 25.547 | 26.045 | |
-29 | 164.856 | 171.320 | 178.019 | 6 | 23.851 | 24.307 | 24.769 | |
-28 | 154.957 | 160.932 | 167.120 | 7 | 22.712 | 23.135 | 23.563 | |
-27 | 145.716 | 151.241 | 156.959 | 8 | 21.634 | 22.026 | 22.423 | |
-26 | 137.086 | 142.196 | 147.481 | 9 | 20.614 | 20.977 | 21.345 | |
-25 | 129.022 | 133.750 | 138.636 | 10 | 19.650 | 19,987 | 20.327 | |
-24 | 121.485 | 125.859 | 130.378 | 11 | 18.733 | 19.044 | 19.359 | |
-23 | 114.435 | 118.485 | 122.665 | 12 | 17.865 | 18.154 | 18,445 | |
-22 | 107.840 | 111.589 | 115.457 | 13 | 17.043 | 17.310 | 17.579 | |
-21 | 101.667 | 105.139 | 108.718 | 14 | 16.264 | 16.510 | 16.759 | |
-20 | 95.886 | 99.102 | 102.415 | 15 | 15.524 | 15.752 | 15.982 | |
-19 | 90.471 | 93.450 | 96.518 | 16 | 14.823 | 15.034 | 15.246 | |
-18 | 85.395 | 88.156 | 90,997 | 17 | 14.157 | 14.352 | 14.548 | |
-17 | 80.636 | 83.195 | 85.826 | 18 | 13.525 | 13.705 | 13.885 | |
-16 | 76.173 | 78.544 | 80.982 | 19 | 12.925 | 13.090 | 13.257 | |
-15 | 71.984 | 74.183 | 76.441 | 20 | 12.354 | 12.507 | 12.660 | |
-14 | 68.052 | 70.091 | 72.184 | 21 | 11.813 | 11.953 | 12.094 | |
-13 | 64.359 | 66.250 | 68.189 | 22 | 11.298 | 11.427 | 11.557 | |
-12 | 60.889 | 62.643 | 64.441 | 23 | 10.808 | 10.927 | 11.046 | |
-11 | 57.628 | 59.255 | 60.922 | 24 | 10.342 | 10.452 | 10.561 | |
-10 | 54.562 | 56.071 | 57.617 | 25 | 9.900 | 10.000 | 10.100 | |
-9 | 51.677 | 53.078 | 54.511 | 26 | 9.470 | 9.570 | 9.670 | |
-8 | 48.963 | 50.263 | 51.592 | 27 | 9.061 | 9.161 | 9.260 | |
-7 | 46.408 | 47.614 | 48.847 | 28 | 8.672 | 8.771 | 8.871 | |
-6 | 44,002 | 45.121 | 46.264 | 29 | 8.302 | 8.401 | 8.499 | |
R - T TABEL KONVERSI | ||||||||
R25= 10KΩ ± 1% B25/50= 3950K ± 1% | ||||||||
T / ℃ | Rmin | Rcen | Rmax | T / ℃ | Rmin | Rcen | Rmax | |
30 | 7.950 | 8.048 | 8.146 | 67 | 1.881 | 1.932 | 1.984 | |
31 | 7.615 | 7.712 | 7.809 | 68 | 1.817 | 1.866 | 1.917 | |
32 | 7.295 | 7.391 | 7.488 | 69 | 1.754 | 1.803 | 1.852 | |
33 | 6.991 | 7.086 | 7.182 | 70 | 1.695 | 1.742 | 1.790 | |
34 | 6.702 | 6.795 | 6.890 | 71 | 1.637 | 1.684 | 1.731 | |
35 | 6.425 | 6.518 | 6.612 | 72 | 1.582 | 1.627 | 1.674 | |
36 | 6.162 | 6.254 | 6.346 | 73 | 1.529 | 1.573 | 1.619 | |
37 | 5.911 | 6.001 | 6.092 | 74 | 1.478 | 1.521 | 1.566 | |
38 | 5.672 | 5.761 | 5.850 | 75 | 1.429 | 1.471 | 1.515 | |
39 | 5.443 | 5.531 | 5.619 | 76 | 1.382 | 1.423 | 1.466 | |
40 | 5.225 | 5.311 | 5.398 | 77 | 1.336 | 1.377 | 1.419 | |
41 | 5.017 | 5.102 | 5.188 | 78 | 1.293 | 1.332 | 1.373 | |
42 | 4.818 | 4.902 | 4.986 | 79 | 1.251 | 1.289 | 1.329 | |
43 | 4.628 | 4.710 | 4.794 | 80 | 1.210 | 1.248 | 1.287 | |
44 | 4.447 | 4.528 | 4.609 | 81 | 1.171 | 1.208 | 1.246 | |
45 | 4.274 | 4.353 | 4.433 | 82 | 1.134 | 1.170 | 1.207 | |
46 | 4.108 | 4.186 | 4.265 | 83 | 1.098 | 1.133 | 1.170 | |
47 | 3.950 | 4.026 | 4.104 | 84 | 1.063 | 1.097 | 1.133 | |
48 | 3.799 | 3.874 | 3.950 | 85 | 1.029 | 1.063 | 1.098 | |
49 | 3.654 | 3.728 | 3.802 | 86 | 0,997 | 1.030 | 1.064 | |
50 | 3.515 | 3.588 | 3.661 | 87 | 0,966 | 0,998 | 1.032 | |
51 | 3.383 | 3.454 | 3.526 | 88 | 0,936 | 0,968 | 1.000 | |
52 | 3.256 | 3.326 | 3.396 | 89 | 0,907 | 0,938 | 0,970 | |
53 | 3.135 | 3.203 | 3.272 | 90 | 0.879 | 0,909 | 0,941 | |
54 | 3.019 | 3.085 | 3.153 | 91 | 0.852 | 0.882 | 0,912 | |
55 | 2.907 | 2.973 | 3.039 | 92 | 0.826 | 0.855 | 0.885 | |
56 | 2.801 | 2.865 | 2.930 | 93 | 0.801 | 0.829 | 0.859 | |
57 | 2.699 | 2.761 | 2.825 | 94 | 0.777 | 0.805 | 0.833 | |
58 | 2.601 | 2.662 | 2.724 | 95 | 0,753 | 0.781 | 0.809 | |
59 | 2.507 | 2.567 | 2.628 | 96 | 0.731 | 0.758 | 0.785 | |
60 | 2.417 | 2.476 | 2.535 | 97 | 0.709 | 0.735 | 0.762 | |
61 | 2.330 | 2.388 | 2.447 | 98 | 0,688 | 0.714 | 0.740 | |
62 | 2.248 | 2.304 | 2.361 | 99 | 0.668 | 0,693 | 0.719 | |
63 | 2.168 | 2.223 | 2.280 | 100 | 0,648 | 0.673 | 0,698 | |
64 | 2.092 | 2.146 | 2.201 | 101 | 0,629 | 0,653 | 0.678 | |
65 | 2.019 | 2.072 | 2.126 | 102 | 0.611 | 0,635 | 0.659 | |
66 | 1.949 | 2.000 | 2.053 | 103 | 0,593 | 0.616 | 0.640 |
Apa itu probe sensor lantai dan bagaimana cara kerjanya?
Setiap termostat pemanas bawah lantai listrik aolittel harus dikonfigurasi untuk menggunakan probe sensor di lantai untuk memantau suhu lantai.Ini adalah cara paling akurat untuk mengontrol suhu berjalan dan secara positif memengaruhi tagihan energi Anda.
Probe sensor memiliki panjang 3m, tebal 4mm dan harus diletakkan di dalam saluran, dalam alur di lantai atau papan isolasi.Anda dapat memperpanjang kabel sensor (menggunakan flex inti ganda 0,75mm) hingga 50m.
Saluran tersebut memiliki diameter 11 mm dan harus digunakan untuk memudahkan pelepasan atau penggantian jika diperlukan.
Probe sensor harus selalu dipasang di area yang bersih di lantai (pintu internal adalah tempat yang bagus) jauh dari pengaruh panas atau dingin lainnya seperti pipa air panas atau ketinggian kaca yang besar dan tidak pernah di bawah permadani!Permadani berfungsi sebagai insulator, menjaga panas di lantai dan menaikkan suhu.
Jika Anda menutupi probe sensor dengan permadani, sisa lantai akan tetap dingin karena termostat hanya memantau bagian lantai yang terpanas.
Sensor sebenarnya ada di dalam modul di ujung kabel dan bekerja dengan terus memantau suhu lantai.
Data suhu dikirim kembali ke termostat yang, ketika bekerja dengan jadwal yang telah ditetapkan, secara otomatis mempertahankan suhu lantai yang Anda inginkan.
3 Tips untuk Memasang Sensor Lantai